\Çy|Ç|àx fxÜ|xá Model Numbers: MQRB4436, MQRB5143, MQRB6961 Stock Numbers: MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE MQR
MQRB4436: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric
PVH58 IPI SYSTEM CONNECTIONS Cold Climate Switch Must Be Disconnected From IPI Wiring Harness. Remove Batteries From Battery Ba
*In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative). The above diagram shows how the Power Vent
PVCM Schematic - IPI 102
103
PVH58 Air Intake Adjustment The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace. L
PVH58 Troubleshooting NOTE: Before connecting Power Vent Control Module, ensure that all other systems and accessories (Remote Control, Fan, Light
PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQRB4436 AND MQRB5143 VENTING AND VENTING AD
58PVH-P3211 3/4” K.O. Bushing 58PVH-WTA Wall Thimble Assembly PVH20H Main Wiring Harness Assembly – Extension Harness (20ft) PVC58MV Power Vent Con
MQRB4436 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -44” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bu
4436MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB4436LPE) 4436MQ-BNGSIE Burner Assembly-Natural Gas c/w Valve System (MQRB44
MQRB4436 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to
MQRB5143 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bu
5143MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB5143N) 5143MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB5143LPE
MQRB6961-Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -69” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bur
6961MQ-BLPSI Burner Assembly- Liquid Propane c/w Valve System (MQRB6961LP) 6961MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB6961N) 696
Common Parts for MQRB4436, MQRB5143 and MQRB6961 Accessories Z1MT Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) Milli
Valve System Parts 1000-P136WR Thermopile GOAI-524 1001-P069SI Electrode Sparker OFP42SA Spark Assist 1001-P216SI Thermocouple 290.216TC SIT 1001-P16
This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed insi
MQRB4436 -See Thru Framing An MQRB4436SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the W
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N
MQRB4436 Single Sided Framing An MQRB4436BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-
MQRB4436 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended
Surround Dimensions MQRB4436 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness fo
MQRB4436 Facing Material Requirements These specifications are the same for all Models (4436N, 4436NE, 4436LP, 4436LPE). Note: If using Optional Surro
MQRB4436 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of m
Table of Contents Table of Contents...
MQRB5143: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric
MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to r
MQRB5143 -See Thru Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the W
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N
MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-
MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommende
Surround Dimensions MQRB5143 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness
MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surr
MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of
MQRB5143 Burner Section: Gas Conversion...
MQRB6961: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric
MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to
MQRB6961 See Thru Framing MQRB6961SK Kit is required for a See Thru Installation. Before you begin Framing- Determine whether the Wall Surface will b
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-
MQRB6961 Single Sided Framing An MQRB6961BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for N
MQRB6961 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended
Surround Dimensions MQRB6961 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness f
MQRB6961 Facing Material Requirements These specifications are the same for all Models (6961N, 6961NE, 6961LP, 6961LPE). Note: If using Optional Surr
MQRB6961 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of m
Recommendations for Finishing of Clean View Linear Products Only non-combustible materials may be used over the face of the appliance. We recomme
MQRB44BK / MQRB51BK / MQRB69BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing”
Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox (Fig.1). 2. Place the Back Liner onto th
MQRB44SK / MQRB51SK / MQRB69SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: To cover the Side Fillers wit
MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation Single Sided: Back Liner, End Panel, and False Bottom Installation: 1. R
MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation See Thru: False Bottom & End Panel Installation: 1. False Bottom Insert
MQRB4436, MQRB5143 & MQRB6961 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to
MQRB4436 / MQRB5143 / MQRB6961 Surround Installation Surround Kits are available in 3 different finishes: MQRB4436 MQRB5143 MQRB6961 Small [1-1/2”]
Fan Installation MQRB4436 / MQRB5143 / MQRB6961 FAN KIT IS FOR USE IN BK (SINGLE SIDED) INSTALLATIONS ONLY Fan Kit should be installed before the fire
Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a
MQRB4436 / MQRB5143 / MQRB6961 -Optional Glass Ember Installation If you wish to use this media evenly spread the glass embers onto the fa
Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove pa
Optional Driftwood & Rock Installation The following Driftwood and Decorative Rock kits are available for the Infinite Series. Model Part Number
Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms o
Infinite Series Door Latch Tool MQRB4436 / MQRB5143 / MQRB6961 A Door Latch Tool is provided to assist with removing and installing the glass
Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert finge
Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CSA
Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING A This appliance has a pilot which must be ligh
Troubleshooting the Gas Control System Problem Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for spark at
Burner System Maintenance- MQRB4436 / MQRB5143 / MQRB6961 It is recommended to annually inspect and clean the Burner System to prevent malfunction and
Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG
Gas Conversion for Modulator – PART C -WARNING!- -WARNING!- 59
Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation
MQRB4436 Burner Section: Gas Conversion Models: MQRB4436N, MQRB4436LP, MQRB4436NE, MQRB4436LPE. Kit Number Description Pilot Orifice Burner Orifice
MQRB5143 Burner Section: Gas Conversion Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Kit Number Description Pilot Orifice Burner Orifice
MQRB4436 / MQRB5143 Burner Tube Removal 1. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Bur
MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace Warning: Failure to position the parts in accordance with these diagrams or failur
MQRB6961 Burner Section: Gas Conversion Models: MQRB6961N, MQRB6961LP, MQRB6961NE, MQRB6961LPE. Kit Number Description Pilot Orifice Burner Orifice B
MQRB6961 Burner Tube Removal 1. Remove the six [8] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Burner Tube awa
Remote Receiver Location For GT Series Remotes Only The Remote Receiver may be located inside of the unit- several inches to the left of the valve an
51-UHS For Infinite Series MQRB4436, MQRB5143, MQRB6961 51-UHS can be inserted & removed from beneath fireplace through access panel
IPI Electronic Ignition SystemOverviewThe IPI system is an advanced burner controller thatprovides you with the option of having either aStanding-Pilo
Electrical Supply in Series: The entire IPI system can be powered by a single power source (i.e. by the AC Adapter). This is advantageous if you do n
Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local
Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, p
IPI Electronic Ignition Parts List – Standard System Item No. Part No. Description 1 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/
EGTRC – Remote Control Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) EGTMRCN or EGTMRCP – Remote Control Thermo
Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan inst
IPI Photos Bottom of Unit with IPI Module Light Module &IPI Valve (MQRB5143 Shown) 74
Close up View of IPI Module Inside of IPI Module 75
IPI Valve IPI Valve 76
Millivolt Valve & Light Module Millivolt Valve 77
LK2 Halogen Lamp Kit MQRB4436 / MQRB5143 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian Nation
LK3 Halogen Lamp Kit (MQRB6961) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Elect
• Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat
Venting A. Clearance above grade, veranda, porch, deck, or balcony 12in [30cm] min.[1,2] B. Clearance to window or door that may be opened. 12in [
General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Ki
Figure 1 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps sh
Minimum clearance to combustibles on venting is 1” with the following exceptions: MQRB4436 MQRB5143 MQRB6961 Top of horizontal 2” 2” 2” Top of 9
MQRB5143 Venting Examples Wall Thimble and Roof Support The Wall Thimble is used in horizontal installations to shield the combustible material from
Installation of Side Wall Venting Vertical rise over 3ft horizontal run (MQRB5143 shown). Note that the minimum height from the bottom of fireplac
Z57ST24 / Z57ST36 Horizontal Snorkel Terminations MQRB4436 / MQRB5143 -FOR INFINITE SERIES II MODELS ONLY- Two snorkel terminations are avail
Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space w
Flue Restrictor Adjustment MQRB4436 / MQRB5143 Only –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening
71 Figure 4 - Clearances in horizontal venting. Figure 5 - a) Straight-through roof support configuration; b) Flex bend configuration; c) Terminat
MQRB4436 / MQRB5143 / MQRB6961 Nailing Tab Guide The Nailing Tabs on the MQRB4436, MQRB5143 or MQRB6961 can be used in two ways: 1/2” Drywall
PVH58 INSTALLATION OVERVIEW The PVH58 Horizontal Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Either Hard Pi
PVH58 VENTING CLEARANCES A. Clearance above a veranda, porch, deck, or balcony or other combustible surface is 27”. Clearance above grade i
PVH58 VENTING HARD PIPE OR FLEX The PVH-58 Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Refer to firepl
PVH58 Venting Adapters ADAPTERS REQUIRED FOR HARD PIPE INSTALLATION Adapters Required At Fireplace MQRB4436, MQRB5143 Z57DFA MQRB6961 Z69DFA
PVH58 VENTING CONFIGURATIONS MAX 3ft Below UnitMIN Venting= 3ft plus one 90° elbowwith Air Intake Shutter fully openMAX Venting = 125
PVH58 WALL THIMBLE INSTALLATION An 11 inch square opening is required. Center Wall Thimble over the 11 inch square opening and secure both pieces on e
PVH58 Wiring Harness Connections WARNING WARNING WARNING A qualified electrician must connect electrical wiring to junction outle
PVH58 Millivolt System Connections WHITEBLACK GREEN/GRND BROWNRED 10ft Double Pole Switch Wiring Harness for Millivolt Systems. Connects t
MILLIVOLT POWER VENT CONTROL MODULE Connect to Power Vent CableConnect to Double Pole Switch CablePlug into120v AC OutletConnect to TH and TH / T
PVCM Schematic - Millivolt 99