Please enjoy your new spa, but think safety first. Read your Owner’s Manual in its entirety before installing your spa and encourage all spa users to d
ELECTRICAL REQUIREMENTSIt is the responsibility of the spa owner to ensure that all electrical connec-tions are made by a qualified electrician in acco
• Rated120V,60Hz,15A(2wiresplusground)• Circuitbreakerorfusesize:15A• Thereceptaclemustbeatleast5feet(1.52m)fromthespa.• T
starting your spa12THERAPY PUMPAllow the spa to circulate on high-speed (see SPA CONTROL OPERATION) for four to five minutes to discharge air from the
# Component Identification Qty. 1 200 Series Jets 33 1N 200 Series Neck Jets 2 2 300 Series Jets 21 3 400 Series Jets 4 4 Control Pan
14the 660™ zonesPUMP 2ZONE 2 PUMP 2 ZONE 1PUMP 1 ZONE 2PUMP 1 ZONE 1
# Component Identification Qty. 1 200 Series Jets 27 1N 200 Series Neck Jets 2 2 300 Series Jets 12 3 400 Series Jets 4 4 Control Pan
16the 545™ zonesPUMP 2ZONE 2 PUMP 1 ZONE 2PUMP 1 ZONE 1
# Component Identification Qty. 1 200 Series Jets 16 1N 200 Series Neck Jets 2 2 300 Series Jets 10 3 400 Series Jets 2 4 Control Pan
18the 530™ zonesPUMP 2 PUMP 1 ZONE BZONE AZONE BZONE A
# Component Identification Qty. 1 200 Series Jets 13 1N 200 Series Neck Jets 2 2 300 Series Jets 16 3 400 Series Jets 4 4 Control Pan
IMPORTANT SAFETY INSTRUCTIONS 120V, Cord Connected Models ... 2 240V, Permanently Instal
16the 435™ zonesZONE 2*ZONE 1*20*Jet selector is optional
# Component Identification Qty. 1 200 Series Jets 10 1N 200 Series Neck Jets 2 2 300 Series Jets 11 3 400 Series Jets 2 4 Control Pan
16the 425™ zonesZONE 2ZONE 122
# Component Identification Qty. 1 200 Series Jets 9 2 300 Series Jets 11 3 400 Series Jets 2 4 Control Panel 1 5 Jet Selector 1 6
16the 322™ zonesZONE 2ZONE 124
START-UP1. At initial power up, the LCD display on the panel will flash “LINK”. Press any on the buttons on the control panel to link the panel to th
Jets 2 (Two Pump Models Only) Press Jets 2 button to turn on pump two high speed. Pressing a second time will turn the pump off. The high speed of p
You exit the programming mode at any time by continuing to press the Light button until you arrive back at the temperature display or by simply pausin
“FLIP” (Invert Display) Your spa will come preset from the factory with the display viewable from inside the spa (recommended). The system will allo
spa control operation291. Temp +/-2. Light: Press until you see “HOLD” in the LCD display.3. Temp +/- to engage the hold mode. The panel will scr
The following instructions contain important safety information. We strong-ly encourage you to read and apply them.IMPORTANT SAFETY INSTRUCTIONSWHEN I
spa control operation305. Temp +/- To display hour window and change hour in increments of 1 hour intervals6. Light: To set and move to next scree
spa control operation31SpeakersGently push the top of the self-rising speakers to raise them. Hold the speaker top, avoiding the speaker screens, and
MODEL 660# Component Qty.1 Control box and heater 12 two-speed pump 13 one-speed pump 14 Slice valves 25 Pump unions
MODEL 435# Component Qty.1 Control box and heater 12 Two-speed pump 14 Slice valves 25 Pump unions 26 Pump plug 1
MODEL 435 2-PUMP# Component Qty.1 Control box and heater 12 Two-speed pump 13 Slice valves 24 GFCI 15 Pump unions
MODEL 322# Component Qty.1 Control box and heater 12 Two-speed pump 13 Slice valves 24 GFCI 15 Pump unions 26 P
troubleshooting guide36PLEASE NOTE: The following corrective actions may be performed by the spa owner. If the trouble cannot be corrected in the step
troubleshooting guide37HTR MAY BE DRY: There is little to no water flow through the heater. Check that the slice valves are fully open. Contact dealer
maintenance38WEEKLY MAINTENANCE1. Removing Debris Remove any debris from the Vortex skimmer and suction guard(s) on the inside of the spa. Blocked in
maintenance391. Leakage DetectionOpen the equipment door and check for signs of water leakage around the pump. Pump seals wear out over time, especia
equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box for bonding to local ground point
maintenance40NOTE: Do not leave an empty spa uncovered. Direct sunlight on the spa surface can cause severe damage or blemishing and cause fittings to
maintenance41IMPORTANT CHEMICAL SAFETY PROCEDURES1. Always keep chemicals out of reach of children.2. Read product labels carefully prior to use.3.
maintenance42WATER CARE TROUBLESHOOTING P: Problem S: SolutionCloudy Water P: Inadequate filtration or dirty filter. S: Ensure that the filter
maintenance43the test strip and give a false reading. Remove spa cover and activate jets and air control. Allow jets to run for 30 minutes. Test water
limited warrantyWHAT THE MARQUIS CORP. LIMITED WARRANTY COVERSMarquis Corp. warrants that our products will be free from defects in materials and work
limited warrantyspa, a replacement part will be provided to you at no charge when you return the de-fective part. All replacement parts assume the ori
stereo system limited warrantySTEREO SYSTEM ONE YEAR LIMITED WARRANTYMarquis Corp. warrants to the original retail purchaser, the components of the st
DISCLAIMERSThere are no additional warranties, express or implied, which extend beyond the terms of this limited warranty. Marquis Corp. makes no warr
created by the pump. Should the need arise to replace the suction guard(s) or the pump, be sure that the flow rates are compatible.17. DANGER: Chi
SAFETY INSTRUCTIONS FOR FRENCH SPEAKING SPA OWNERSAVERTISSEMENT: Ne pas placer d’appareil électrique (luminaire, télé-phone, radio, téléviseur, etc.)
PERSONAL SAFETYProlonged immersion in hot water can result in HYPERTHERMIA, a dan-gerous condition which occurs when the internal temperature of the b
LOCATIONFor your portable spa to function properly and safely, it must be located on a hard, flat, level surface. Inground spas require special install
5. Lay a straight piece of lumber across the frame and level any high spots in the gravel by pushing the straight lumber across the frame. Fill in an